APC · MPN: APDU10450SW
£3,771.99
inc. VAT
Spread the cost with Klarna, Float or SnapFrom 3 interest-free payments of £1,257.33 See options

Credit subject to status. 18+, UK residents only. See each provider for terms.

Out of stock

FREE delivery

Express £9.99

Price drop alert

APC NetShelter Rack PDU Advanced, Switched, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309
Now £3,771.99

We'll only use your email for this alert unless you tick the box. Unsubscribe any time.

We'll watch the price for 6 months and email you if it drops. Unsubscribe in one click.

Overview

  • Maximum Outlet Density All models include 40, 42, or 48 outlets
  • Space Saving
  • High Power Capacity Models now available to provide up to 34.6kW
  • APC Locking Power Cord Compatible Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet
  • Circuit Breaker Monitoring
  • Alternating Phase
  • 60ºC (140ºF) Operating Temperature
  • Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU
  • Hydraulic Magnetic Circuit Breakers
  • Live Swap Network Management Card
  • Environmental Sensor Support
  • Color LCD Display
  • Dual Network Ports

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Specifications

Design

On/off switchNo
DisplayLCD
Product colourBlack
MountingVertical
Rack capacity0U
TypeSingle-phase
PDU typesSwitched

Ports & interfaces

AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugIEC 60309
AC outlets quantity48 AC outlet(s)
Show all 30 specificationsShow fewer specifications

Features

Daisy chainYes

Power

Maximum total current draw per phase48 A
Maximum input current per phase60 A
Load capacity34600 VA
Output voltage240 V
Nominal output voltage240 V
Maximum current60 A
AC input frequency50 - 60 Hz
Nominal input voltage200 - 240 V

Certificates

CertificationCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1

Operational conditions

Non-operating altitude0 - 15240 m
Operating altitude0 - 3048 m
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Storage temperature (T-T)-25 - 65 °C
Operating temperature (T-T)-5 - 60 °C

Weight & dimensions

Weight12.4 kg
Height1826 mm
Depth75 mm
Width56 mm

Delivery & returns

Delivery

  • FREE standard delivery on orders over £50, otherwise £4.95 (3–5 working days).
  • Express delivery £9.99 (1–3 working days) on selected products, UK mainland.
  • PlayStation and Arozzi products use a 5–7 working-day service.
  • Orders are processed within 24 hours, Monday to Friday excluding bank holidays. All deliveries must be signed for.

Returns

  • Changed your mind? Tell us within 14 days of receiving your item, then return it within a further 14 days, unused and in its original packaging. A minimum £9.99 collection fee applies.
  • Faulty or damaged on arrival? Contact us within 48 hours of delivery.
  • Custom-built PCs can only be returned if faulty. Opened headphones, earphones and AirPods can't be returned for hygiene reasons.

Full delivery information · Full returns policy