{"product_id":"riello-npw-2000-uninterruptible-power-supply-ups-2-kva-1200-w-6-ac-outlets","title":"Riello NPW 2000 uninterruptible power supply (UPS) 2 kVA 1200 W 6 AC outlet(s)","description":"\u003cdiv id=\"icepim-bulletpoints\"\u003e\u003cul\u003e\n\u003cli\u003e2 kVA 1200 W\u003c\/li\u003e\n\u003cli\u003eWaveform: Sine\u003c\/li\u003e\n\u003cli\u003e6 AC outlet(s)\u003c\/li\u003e\n\u003cli\u003eSealed Lead Acid (VRLA)\u003c\/li\u003e\n\u003cli\u003eCompact Grey\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-long-desc\"\u003e\u003cp id=\"ice_long_description\"\u003eThe NetPower series includes the 600-2000VA models and uses digital Line Interactive (VI) technology.\u003cbr\u003eThe load is powered from the mains through an AVR to stabilise brownout, sag and surge voltages, and EMI filters to suppress spikes and transients. When the mains fails, the load is powered by the inverter with a pseudo sinewave to provide sufficient runtime for computer system shutdown using the PowerShield.\u003cbr\u003e\u003cbr\u003e- mains power supply stabilisation and filtering (Line Interactive (VI) technology with AVR and filters for atmospheric disturbance suppression).\u003cbr\u003e- cold start capability: the UPS can power up without a mains supply present.\u003cbr\u003e- high reliability with built-in battery test feature.\u003cbr\u003e- supplied with 2 output cables.\u003cbr\u003e- USB port.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-attributes\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency regulation\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e211 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e276 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e170 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e1200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e2 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB 2.0 ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e6 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eC14 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eBattery\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery recharge time\u003c\/td\u003e\n\u003ctd\u003e4 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical backup time at half load\u003c\/td\u003e\n\u003ctd\u003e20 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical backup time at full load\u003c\/td\u003e\n\u003ctd\u003e9 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of batteries supported\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery technology\u003c\/td\u003e\n\u003ctd\u003eSealed Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eCompact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 6000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEN 62040-1-1 2006\/95\/EC;EN 62040-2 C2  2004\/108 ECCE\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e397 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e480 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e230 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Riello","offers":[{"title":"Default Title","offer_id":56229342314878,"sku":"NPW 2000","price":275.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/0190\/0965\/files\/2219599ba2121ab5cf9c2a599bb1f30c_a6337578-6032-4ccf-bf0e-1d3083e47963.jpg?v=1757489537","url":"https:\/\/www.backtotheoffice.co.uk\/products\/riello-npw-2000-uninterruptible-power-supply-ups-2-kva-1200-w-6-ac-outlets","provider":"Back to the Office","version":"1.0","type":"link"}