{"product_id":"lenovo-7zt7a00537-network-card-internal-fiber-10000-mbits","title":"Lenovo 7ZT7A00537 network card Internal Fiber 10000 Mbit\/s","description":"\u003cdiv id=\"icepim-bulletpoints\"\u003e\u003cul\u003e\n\u003cli\u003eVXLAN\/NVGRE Hardware Offloads: These stateless offloads preserve application performance for overlay networks. With these offloads, it is possible to distribute network traffic across CPU cores. At the same time, X710 offloads LSO, GSO, and checksum from the host software, which reduces CPU overhead\u003c\/li\u003e\n\u003cli\u003eMobile and cloud application acceleration: Intel’s Data Plan Development Kit (DPDK) delivers an open driver where users can fine-tune small packet performance, which delivers line-rate at 128 byte, and near line-rate at 64 byte\u003c\/li\u003e\n\u003cli\u003eLow latency: Intel Ethernet Flow Director delivers hardware-based application steering and Intel Data Direct I\/O makes the processor cache the primary destination and source of I\/O data rather than main memory. Combined, latency is reduced and Intel reports a three-fold improvement in RPS\u003c\/li\u003e\n\u003cli\u003eVirtualization performance: With Intel Virtualization Technology (VT), the X710 family of adapters delivers outstanding I\/O performance in virtualized server environments. These adapters reduce I\/O bottlenecks by providing intelligent offloads for networking traffic per virtual machine (VM), which enables near-line rate speeds for small packets and supports almost an unlimited amount of isolated traffic flows so that you can scale your cloud environment\u003c\/li\u003e\n\u003cli\u003eNext-generation VMDq: The X710 adapters support up to 256 VMDq VMs and offer enhanced Quality of Service (QoS) feature by providing weighted round-robin servicing for the Tx data. The adapters offload the data-sorting functionality from the hypervisor to the network silicon, which improves data throughput and CPU usage\u003c\/li\u003e\n\u003cli\u003ePCI-SIG SR-IOV implementation: Provides an implementation of the PCI-SIG standard for I\/O Virtualization. The physical configuration of each port is divided into multiple virtual ports. Each virtual port is assigned to an individual VM directly by bypassing the virtual switch in the Hypervisor, which results in near-native performance\u003c\/li\u003e\n\u003cli\u003eVM load balancing: Provides traffic load balancing (Tx and Rx) across VMs that are bound to the team interface. It also provides fault tolerance if a switch, port, cable, or adapter fails\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-long-desc\"\u003e\u003cp id=\"ice_long_description\"\u003eThe Intel X710 family of 10 Gigabit Ethernet (GbE) server network adapters addresses the demanding needs of the next-generation data center. By providing unmatched features for server and network virtualization, small packet performance, and low power; the data center network is flexible, scalable, and resilient.\u003cbr\u003e\u003cbr\u003eThe X710 is available in three host connections: a standard PCIe host interface, a Mezzanine LOM (ML2) host interface for ThinkSystem and System x servers, and an AnyFabric host interface for ThinkServer systems.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-attributes\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber ports quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber optic connector\u003c\/td\u003e\n\u003ctd\u003eSFP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eFiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost interface\u003c\/td\u003e\n\u003ctd\u003ePCI Express\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity technology\u003c\/td\u003e\n\u003ctd\u003eWired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eNetwork\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN tagging\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eiSCSI support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e9728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWake-on-LAN ready\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q, IEEE 802.1ad, IEEE 802.1as, IEEE 802.1p, IEEE 802.3ae, IEEE 802.3x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum data transfer rate\u003c\/td\u003e\n\u003ctd\u003e10000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEN55022EN55024EN 61000-3-2EN 61000-3-3ICES-003, Issue-004FCC 47 CFR Part 15 Class AVCCIAS\/NZS CISPR 22 \/ C-tickRRL for KCBSMIUL 94 V-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack, Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eSystem requirements\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eCompatible operating systems\u003c\/td\u003e\n\u003ctd\u003eMicrosoft Windows Server 2008 R2Microsoft Windows Server 2012Microsoft Windows Server 2012 R2Microsoft Windows Server 2016Red Hat Enterprise Linux 6 Server x64 EditionRed Hat Enterprise Linux 7SUSE Linux Enterprise Server 11 for AMD64\/EM64TSUSE Linux Enterprise Server 11 with Xen for AMD64\/EM64TSUSE Linux Enterprise Server 12SUSE Linux Enterprise Server 12 with XENVMware vSphere 5.5 (ESXi)VMware vSphere 6.0 (ESXi)VMware vSphere 6.5 (ESXi)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 2134 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e10 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-20 - 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e167 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOther features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntelligent Offloads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per pack\u003c\/td\u003e\n\u003ctd\u003e1 pc(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel® Virtualization Technology (Intel® VT)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Virtual Machine Device Queues (VMDq)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceive Side Scaling (RSS)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Data Direct I\/O Technology\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Lenovo","offers":[{"title":"Default Title","offer_id":55308771852670,"sku":"7ZT7A00537","price":427.99,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/0190\/0965\/files\/adf0564d38c950c8792c3e9bf711912f.jpg?v=1756125468","url":"https:\/\/www.backtotheoffice.co.uk\/products\/lenovo-7zt7a00537-network-card-internal-fiber-10000-mbits","provider":"Back to the Office","version":"1.0","type":"link"}