{"product_id":"apc-netshelter-switched-rack-pdu-zero-u-125kw-208v-21-c13-and-3-c19-outlet-3ft-input-cord","title":"APC NetShelter Switched Rack PDU, Zero U, 12.5kW, 208V, 21 C13 and 3 C19 outlet, 3ft input cord","description":"\u003cdiv id=\"icepim-long-desc\"\u003e\u003cp id=\"ice_long_description\"\u003e\u003cb\u003eLocal Current Monitoring Display\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAlarm Thresholds\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePower Delays\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRemote Individual Outlet Control\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRemote Management Capabilities\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-attributes\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePDU types\u003c\/td\u003e\n\u003ctd\u003eMonitored, Switched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection type\u003c\/td\u003e\n\u003ctd\u003eCS8365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler, C19 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e24 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e0.91 m\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware upgradeable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware upgradeable via\u003c\/td\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet control\u003c\/td\u003e\n\u003ctd\u003eRecycle, Turn off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower protection features\u003c\/td\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum total current draw per phase\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad capacity\u003c\/td\u003e\n\u003ctd\u003e12500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input frequency\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003ecUL, CSA, FCC Part 15 Class A, ICES-003, UL 60950, UL, REACH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 15000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-25 - 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-5 - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1778 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePackaging content\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003ePackaging content\u003c\/td\u003e\n\u003ctd\u003eCord Retention Bracket(s), Documentation CD, Installation Guide, Rack Mounting Brackets, RS-232 configuration cable, Toolless Mounting Kit\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e2108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv id=\"icepim-pdf-urls\"\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_35576332_1505916510_0652_12212.pdf\" target=\"_blank\"\u003emanual pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_35576332_1505916535_8332_20224.pdf\" target=\"_blank\"\u003eleaflet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":55468868305278,"sku":"AP7968B","price":1678.99,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/0190\/0965\/files\/a2235f12d5d34e8447a0a25e5806a49e.jpg?v=1769172444","url":"https:\/\/www.backtotheoffice.co.uk\/products\/apc-netshelter-switched-rack-pdu-zero-u-125kw-208v-21-c13-and-3-c19-outlet-3ft-input-cord","provider":"Back to the Office","version":"1.0","type":"link"}